For installation of the Oil Sight Glass, installers should:
Locate the drain plug at the bottom of the oil reservoir or the elbow for drain ports located on sides of the equipment.
Apply a threading compound (such as “pipe dope”) to both the nipple and drain valve. Note: Avoid using any products containing Teflon, including Teflon tape.
Screw the sight glass into the drain plug port by hand, then tighten with a standard open-end wrench using the drain plug flats.
By tightening the drain plug, the torque will also transfer through the sight glass on to the nipples. Note: Excessive torque is not required.
|

|